UNICAD EOOD
Line 04

UPS for heating systems – SineUPS with a pure sine wave

Uninterruptible power supplies of 100–850 W for central heating and stoves with a water jacket, circulation pumps, gas boilers, pellet stoves and garage doors. Made in Bulgaria.

Why does a boiler need a dedicated UPS rather than a computer one?

Most standard UPS units produce a so-called modified sine wave. It is ruinous for circulation pumps – they start to hum, heat up and often burn out.

  • 100 % pure sine wave: The pump runs as quietly and safely as it does on the grid.
  • Long battery life: A smart charger that does not “bake” the battery but keeps it ready for years.
  • The backup time you choose: We fit the system with an external battery for 2 to 12 hours of operation.

Made in Bulgaria

We offer Bulgarian uninterruptible power supplies made by Technogamma Ltd. in Plovdiv – designed for harsh conditions and a long service life. They suit all common circulation pumps (standard and electronic), gas boilers, pellet stoves and combined control systems. Warranty and post-warranty service come directly from the manufacturer.

Models and prices

All prices are in euro including VAT. 24-month warranty. The battery is not included, except the one built into the s100a Plus.

  • SineUPS s100

    12 Vdc → 220 Vac · 100 W
    SineUPS s100

    Pure sine wave inverter with terminals for an external battery and a built-in charger. For loads up to 100 W – all standard and electronic circulation pumps.

    Price: €144.00 incl. VAT

  • SineUPS s100a Plus

    12 Vdc → 220 Vac · 100 W

    Pure sine wave inverter with a built-in 7 Ah battery, terminals for an additional external battery and a built-in charger. For loads up to 100 W – all standard and electronic circulation pumps.

    Price: €164.00 incl. VAT

  • SineUPS s200

    12 Vdc → 220 Vac · 200 W
    SineUPS s200

    Pure sine wave inverter with terminals for an external battery and a built-in charger. For loads up to 200 W – all standard and electronic circulation pumps.

    Price: €169.00 incl. VAT

  • SineUPS s400

    12 Vdc → 220 Vac · 400 W
    SineUPS s400

    Pure sine wave inverter with terminals for an external battery and a built-in charger. For loads up to 400 W – gas boilers, powerful standard and electronic circulation pumps.

    Price: €267.00 incl. VAT

  • SineUPS s600

    12 Vdc → 220 Vac · 600 W
    SineUPS s600

    Pure sine wave inverter with terminals for an external battery and a built-in charger. For loads up to 600 W – pellet stoves, powerful circulation pumps, including electronically controlled ones.

    Price: €311.00 incl. VAT

  • SineUPS s850

    12 Vdc → 220 Vac · 850 W
    SineUPS s850

    Pure sine wave inverter with terminals for an external battery and a built-in charger. For loads up to 850 W – pellet stoves, powerful circulation pumps, including electronically controlled ones.

    Price: €360.00 incl. VAT

How many hours will the pump run?

Approximate running time 7.2 h

By the manufacturer’s method: t = 12 × C / P. For example, a 100 W pump with a 60 Ah battery runs 12 × 60 / 100 = 7.2 hours. The time is approximate: capacity depends on the charge, the temperature and the age of the battery. And the other way round: C = t × P / 12 – a 100 W pump running for 4 hours needs a battery of 4 × 100 / 12 = 33 Ah.

Recommended battery capacity

ModelBattery, AhLoadRunning time
SineUPS s10040100 W5 h
SineUPS s100a Plus40100 W1 h + 5 h
SineUPS s20060200 W2 h 30 min
SineUPS s400150400 W3 h 30 min
SineUPS s600200600 W2 h 30 min
SineUPS s850200850 W~2 h

Approximate values.

Frequently asked questions

Why SineUPS and a pure sine wave?

When the grid fails, a sine-wave inverter (UPS) generates a pure sine wave – a voltage of the same shape as the grid. Most UPS units on the market, including standard computer ones, give a modified sine wave, which is really square pulses. Inductive loads (motors, pumps, transformers) and electronics are made for a sine-wave voltage; on anything else they draw more and heat up, and the precise electronics of gas and pellet boilers do not start.

What can it power?

Circulation pumps; pellet burners (the UPS needs to be 600 W, 850 W or 1200 W); gas boilers for heating and hot water with electronic control; oil burners with electronic control; ventilation; computers, audio and TV (switch-over time 5 ms).

Which model do I need?

It depends on the power of the load (W) and the time it must run during an outage. Choose a model whose output power exceeds your needs. If the load is 95–100 W, do not stay at the limit: choose a 200 W UPS, the s200, with an external battery. The s100a Plus has a built-in 7 Ah battery and terminals for an external one – double security.

And for pellet stoves?

The igniter of a stove takes about 300 W whatever the specifications say, and in combined pellet boilers it can reach 1100 W. The starting power often exceeds 450 W, so these systems need a model above 500 W, such as the s600. The auger draws a fair amount of power too, and the control electronics need a stable supply.

Which battery should I choose?

SineUPS works with 12 V batteries (the s1200 with two in series). Flooded lead-acid batteries, car batteries included, give off gas and are not for closed living spaces. AGM and gel batteries are valve-regulated, give off no gas and can stay indoors – the better but more expensive choice. A car battery lasts fewer than 70 cycles of discharge to 50 %, a traction battery 120–160, and an AGM or gel UPS battery more than 360. This matters where power cuts are frequent.

How to order

  1. Call us about stock and delivery time, or send your order to info@unicad.bg.

  2. Pay in cash or by card (POS) and collect the goods at our office and shop in Sofia.

  3. Or have them delivered cash on delivery by a courier of your choice – we usually work with Econt.

The other product lines

Stock, delivery time, an offer for installation – ask us.

+359 89 8887710

+359 2 962 19 28 · or write to info@unicad.bg

Privacy